Bureau Veritas

Primary Integration - Internship Program

Internship All branches

Website provided by the program.

At a glance

Open to
All branches
Format
Hybrid
Length
Duration not listed
Locations
1 location in Texas · jobs available nationwide
Career field
Architecture and Engineering, Construction and Extraction, Management
Target MOS/ratings
USN - All Nuclear ratings, MMA, MM, EM (E-5 or above) USAF - AGE (E4 or above) USMC - 1161, 1141, 1171, 5341 (E5 or above) US Army - 91J, 52D, 94E (E5 or above) Coast Guard - MK, AMT (E5 or above)

About the program

The Role and Responsibility of a Cx Engineer in Data Center CommissioningCore PurposeThe Commissioning (CxA) Authority is a third-party firm hired to represent the client. Third party means they are not the designer, not the contractor, and not the equipment vendor. The Cx engineer’s only role is to represent the client’s interests by testing and reporting on how the systems perform.A Cx engineer’s role is to test, observe, and identify. They do not install, repair, or redesign equipment. They are not builders, fixers, or designers - those responsibilities stay with the contractor, vendor, or Engineer of Record (EOR). Their responsibility is to stand apart, provide an unbiased evaluation, and ensure that system integrity and owner requirements are met.What a Cx Engineer Is Responsible For1.Testing and Verificationo Execute scripted tests to confirm proper system functionality, redundancy, and failover.o Identify and clearly document deficiencies, risks, or non-conformance.o The Commissioning Authority (CxA) leads, plans, schedules, and coordinates the commissioning team.The on-site commissioning team includes:o The General Contractoro The equipment vendorso The mechanical or electrical contractoro The BMS/EPMS vendorThe CxA’s responsibilities include:o Organizing and leading the teamo Preparing and updating the Commissioning Plano Verifying design documents align with Owner’s Project Requirements (OPRs)o Defining testing requirementso Maintaining an Issues Log to capture deviationso Conducting tests, documenting outcomeso Preparing the final Commissioning Process Report and Systems Manualo Recommending system acceptance to the owner2. Issue Identification and Trackingo Capture problems in an issues logo Follow through until resolutiono Ensure each item is closed by the responsible party3. Safety and Load Protectiono Maintain safety standards and never allow tests to endanger staff, equipment, or live load4. Objective Reportingo Report findings factually and transparently to owners, contractors, and vendorso Stay impartial — advocate only for the facility’s operational reliability.What a Cx Engineer Is Not Responsible For1. Correcting Issueso Cx engineers do not repair, rewire, or adjust systemso Responsibility for correcting deficiencies lies with vendors, contractors, or installers2.Altering Designo If a test exposes a design flaw, the solution belongs to the EOR3.Operating EquipmentoCx engineers do not operate or take ownership of systemsoThey may direct or witness vendors performing actions during tests, but they do not manipulate equipment themselves4.Owner’s Business DecisionsoBudget, schedule, or contractual impacts remain outside the Cx engineer’s roleoTheir authority is technical, not financialIndustry Standards BackingThis philosophy is not just opinion - it is reinforced by multiple professional associations and standards bodies:• ASHRAE - Guideline 0 and Standard 202 define commissioning as a quality-focused process of evaluation and documentation to verify that systems meet the Owner’s Project Requirements (OPRs). The Cx Authority plans, tests, and reports - but does not correct or redesign.• BCxA (Building Commissioning Association) - Positions the Cx professional as the owner’s advocate, responsible for impartial verification and documentation. Their code of ethics emphasizes independence and neutrality.• ACG (AABC Commissioning Group) - In their Guidelines for Total Building Commissioning, ACG defines the Cx role as ensuring systems are installed and function per OPRs, with corrections belonging to contractors and vendors.• NEBB (National Environmental Balancing Bureau) - Through certification programs, NEBB reinforces that commissioning professionals test and validate systems, but installation and correction remain the contractor’s responsibility.• USGBC / LEED – Commissioning is required for certification, and the CxA must be independent of design and construction teams. The CxA verifies and documents, while designers and contractors correct deficiencies.• Uptime Institute (Data center-specific) - Their Tier Certification of Constructed Facility (TCCF) process depends on commissioning to prove redundancy and resiliency. The Cx team’s role is to verify Tier compliance - not to alter equipment or correct vendor work.

Jobs this program prepares you for

The Role and Responsibility of a Cx Engineer in Data Center CommissioningCore PurposeThe Commissioning (CxA) Authority is a third-party firm hired to represent the client. Third party means they are not the designer, not the contractor, and not the equipment vendor. The Cx engineer’s only role is to represent the client’s interests by testing and reporting on how the systems perform.A Cx engineer’s role is to test, observe, and identify. They do not install, repair, or redesign equipment. They are not builders, fixers, or designers - those responsibilities stay with the contractor, vendor, or Engineer of Record (EOR). Their responsibility is to stand apart, provide an unbiased evaluation, and ensure that system integrity and owner requirements are met.What a Cx Engineer Is Responsible For1.Testing and Verificationo Execute scripted tests to confirm proper system functionality, redundancy, and failover.o Identify and clearly document deficiencies, risks, or non-conformance.o The Commissioning Authority (CxA) leads, plans, schedules, and coordinates the commissioning team.The on-site commissioning team includes:o The General Contractoro The equipment vendorso The mechanical or electrical contractoro The BMS/EPMS vendorThe CxA’s responsibilities include:o Organizing and leading the teamo Preparing and updating the Commissioning Plano Verifying design documents align with Owner’s Project Requirements (OPRs)o Defining testing requirementso Maintaining an Issues Log to capture deviationso Conducting tests, documenting outcomeso Preparing the final Commissioning Process Report and Systems Manualo Recommending system acceptance to the owner2. Issue Identification and Trackingo Capture problems in an issues logo Follow through until resolutiono Ensure each item is closed by the responsible party3. Safety and Load Protectiono Maintain safety standards and never allow tests to endanger staff, equipment, or live load4. Objective Reportingo Report findings factually and transparently to owners, contractors, and vendorso Stay impartial — advocate only for the facility’s operational reliability.What a Cx Engineer Is Not Responsible For1. Correcting Issueso Cx engineers do not repair, rewire, or adjust systemso Responsibility for correcting deficiencies lies with vendors, contractors, or installers2.Altering Designo If a test exposes a design flaw, the solution belongs to the EOR3.Operating EquipmentoCx engineers do not operate or take ownership of systemsoThey may direct or witness vendors performing actions during tests, but they do not manipulate equipment themselves4.Owner’s Business DecisionsoBudget, schedule, or contractual impacts remain outside the Cx engineer’s roleoTheir authority is technical, not financialIndustry Standards BackingThis philosophy is not just opinion - it is reinforced by multiple professional associations and standards bodies:• ASHRAE - Guideline 0 and Standard 202 define commissioning as a quality-focused process of evaluation and documentation to verify that systems meet the Owner’s Project Requirements (OPRs). The Cx Authority plans, tests, and reports - but does not correct or redesign.• BCxA (Building Commissioning Association) - Positions the Cx professional as the owner’s advocate, responsible for impartial verification and documentation. Their code of ethics emphasizes independence and neutrality.• ACG (AABC Commissioning Group) - In their Guidelines for Total Building Commissioning, ACG defines the Cx role as ensuring systems are installed and function per OPRs, with corrections belonging to contractors and vendors.• NEBB (National Environmental Balancing Bureau) - Through certification programs, NEBB reinforces that commissioning professionals test and validate systems, but installation and correction remain the contractor’s responsibility.• USGBC / LEED – Commissioning is required for certification, and the CxA must be independent of design and construction teams. The CxA verifies and documents, while designers and contractors correct deficiencies.• Uptime Institute (Data center-specific) - Their Tier Certification of Constructed Facility (TCCF) process depends on commissioning to prove redundancy and resiliency. The Cx team’s role is to verify Tier compliance - not to alter equipment or correct vendor work.

Eligibility & prerequisites

No moving violations with in 5 yearsAbility to pass drug screeningMobility to lift 50lbs or more

All 48 states in the Continental United States. We will work together to ensure your dates work with our needs and as well as our dates work with your needs. This will be a quarterly listing to give planned expectations for the service member and Bureau Veritas.

Locations & contacts

Loading map…

How to apply

  1. Contact the provider using the website or email above. Ask about openings, start dates, and the application.
  2. Confirm eligibility. SkillBridge is generally for service members within 180 days of separation who have their command's approval.
  3. Get your unit commander's authorization following your branch's SkillBridge process. Start early; approvals take time.
  4. Read reviews from past participants on Rate My SkillBridge.

Policy details: official DoW SkillBridge site · our FAQ