(AEP)
All branchesNational Security
Website provided by the program.
At a glance
- Open to
- All branches
- Format
- In person
- Length
- 31 - 60 days
- Locations
- 1 location in Indiana
- Job locations
- Arkansas, Indiana, Kentucky, Louisiana, Michigan, Ohio, Oklahoma, Tennessee, Texas, Virginia, West Virginia
- Target MOS/ratings
- Army: 12P 12Q 12R 15B 15D 15E 15F 15H 15J 15X 15Y 15M 15R 15S 15T 15U 15V 91A 91C 91D 91M 94M 94P 94S 94T 14T 15N 14H 14G // Air Force: 2A3X4 2A3X5 3E0X1 3E051 3E0X2 2A6X6 2A9X1 2A9X2 2A9X3 2A591 2A551 3D1X1 2A5X3 2610 2R191 2W051 2W151 A7X3 2A7X2 2A554 2A5X4 2A551 // Navy: AE AT AO CE EM EMN AT ET ETN GSE FCA FT // Marines: 1141 1142 1169 6122 6123 6124 6332 6333 6336 6330 6432 6433 6434 2887 2841 2146 // Coast Guard: AET EM
About the program
Perform all types of work involved in the construction, maintenance, rebuild, removal, operation, testing and inspection of energized or de-energized generation, transmission and distribution facilities. Assist in responding to emergency call-outs on station trouble and coordinating prompt restoration of service to customers as required.
Jobs this program prepares you for
ESSENTIAL JOB FUNCTIONS:Work on energized equipment up to 260 volts. After six months in classification, employee shall assist in work on conductors and equipment energized at voltages above 750 volts with direct supervision or assistance of personnel in higher classification. Select proper prints and/or drawings for various work and have a basic understanding of each. Use voltmeters, ohmmeters, ammeters, insulation meggers and other test equipment associated with station work.Assist in disassembling and reassembling, inspecting, maintenance, and repairing of station transformers, circuit breakers, portable substations, rotating machinery, network protectors and transformers, air ducts and heat exchangers; install and maintain station batteries; replace nitrogen bottles and air filters.Assist in station work such as installing conduit, pipe, cable and wire; use hand lines to pass tools and materials; dig and backfill trenches; remove and spread stone; uncrate equipment and material; install and remove portable substation fences, barriers and safety signs; paint structures and equipment; climb station structures. Use various kinds of tapes, insulating materials, protective and insulating paints and varnishes, and understand proper application of each.Assist in making visual inspections such as check lights, heaters, circuit breaker counters, oil levels, and bus connections; read gauges such as voltmeters, ammeters, hydrometers, pressure and level gauges; apply start-run-stop tests on emergency generators, water and sump pumps and fire engine motors. Report abnormal conditions. Replace lamps, switches, duplex outlets, dry cells; install and maintain signal and communication systems. Assist in various tests involving oil samples, connecting and operating portable and stationary oil handling equipment. Assist in electrical tests, TTR, Doble, core megger and resistance for transformer testing, etc.Assist in station switching including use of radio communication and/or direct instruction from higher classification, assist in checking equipment clearances and making de-energized tests, place grounds as directed.
Eligibility & prerequisites
All equipment and PPE provided.
Locations & contacts
Loading map…
- Southbend, INJason Bettgerjwbettger@aep.com
How to apply
- Contact the provider using the website or email above. Ask about openings, start dates, and the application.
- Confirm eligibility. SkillBridge is generally for service members within 180 days of separation who have their command's approval.
- Get your unit commander's authorization following your branch's SkillBridge process. Start early; approvals take time.
- Read reviews from past participants on Rate My SkillBridge.
Policy details: official DoW SkillBridge site · our FAQ